DW-AS-509-M8 Application TypeAnalog Rated operating distance sn4 mm MountingQuasi-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permissible ripple...
[2016-03-11] -
DW-AS-509-C8-390 Rated operating distance sn4 mm MountingQuasi-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB15 … 30 VDC Permissible ripple content≤ 20 % UB ...
[2016-03-11] -
DW-AD-519-M30-390 Application TypeAnalog Rated operating distance sn40 mm MountingNon-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB15 … 30 VDC Permissible ri...
[2016-03-11] -
DW-AD-519-M30-320 Application TypeAnalog Rated operating distance sn40 mm MountingNon-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB15 … 30 VDC Permissible ri...
[2016-03-11] -
DW-AD-519-M30-120 Application TypeAnalog Rated operating distance sn40 mm MountingNon-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permissible ri...
[2016-03-11] -
DW-AD-519-M30 Application TypeAnalog Rated operating distance sn40 mm MountingNon-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permissible ripple...
[2016-03-11] -
DW-AD-519-M18-390 Application TypeAnalog Rated operating distance sn20 mm MountingNon-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB15 … 30 VDC Permissible ri...
[2016-03-11] -
DW-AD-519-M18-320 Application TypeAnalog Rated operating distance sn20 mm MountingNon-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB15 … 30 VDC Permissible ri...
[2016-03-11] -
DW-AD-519-M18-120 Application TypeAnalog Rated operating distance sn20 mm MountingNon-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permissible ri...
[2016-03-11] -
DW-AD-519-M18 Rated operating distance sn20 mm MountingNon-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permissible ripple content≤ 20 % UB No-l...
[2016-03-11] -
DW-AD-509-M30-390 Application TypeAnalog Rated operating distance sn20 mm MountingQuasi-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB15 … 30 VDC Permissible ...
[2016-03-11] -
DW-AD-509-M30-320 Application TypeAnalog Rated operating distance sn20 mm MountingQuasi-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB15 … 30 VDC Permissible ...
[2016-03-11] -
DW-AD-509-M30-120 Application TypeAnalog Rated operating distance sn20 mm MountingQuasi-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permissible ...
[2016-03-11] -
DW-AD-509-M30 Application TypeAnalog Rated operating distance sn20 mm MountingQuasi-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permissible ripp...
[2016-03-11] -
DW-AD-509-M18-390 Application TypeAnalog Rated operating distance sn10 mm MountingQuasi-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB15 … 30 VDC Permissible ...
[2016-03-11] -
DW-AD-509-M18-320 Application TypeAnalog Rated operating distance sn10 mm MountingQuasi-embeddable Hysteresis- Repeat accuracy norm≤ 5 % sr Supply voltage range UB15 … 30 VDC Permissible ...
[2016-03-11]