Contrinex堪泰
-
DW-AS-633-M8-001 Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … ...
[2016-03-09] -
DW-AS-633-065-001 Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 …...
[2016-03-09] -
DW-AS-632-M18-002 Application TypeStandard Rated operating distance sn12 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 ...
[2016-03-09] -
DW-AS-632-M12-120 Application TypeStandard Rated operating distance sn8 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 …...
[2016-03-09] -
DW-AS-632-M12 Application TypeStandard Rated operating distance sn8 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 ...
[2016-03-09] -
DW-AS-632-M8-001 Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … ...
[2016-03-09] -
DW-AS-632-065-001 Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 …...
[2016-03-09] -
DW-AS-631-M18-002 Application TypeStandard Rated operating distance sn12 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 ...
[2016-03-09] -
DW-AS-631-M12-120 Application TypeStandard Rated operating distance sn8 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 …...
[2016-03-09] -
DW-AS-631-M12 Application TypeStandard Rated operating distance sn8 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 ...
[2016-03-09] -
DW-AS-631-M8-001 Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … ...
[2016-03-09] -
DW-AS-631-065-001 Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 …...
[2016-03-09] -
DW-AS-624-M18-120 Application TypeStandard Rated operating distance sn8 mm MountingEmbeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 ...
[2016-03-09] -
DW-AS-624-M18-002 Application TypeStandard Rated operating distance sn8 mm MountingEmbeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 ...
[2016-03-09] -
DW-AS-624-M12-120 Application TypeStandard Rated operating distance sn4 mm MountingEmbeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permis...
[2016-03-09] -
DW-AS-624-M12 Application TypeStandard Rated operating distance sn4 mm MountingEmbeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permissibl...
[2016-03-09]