1SBL103004R8101模块化接触器来自ABB品质,上海锐誉德国原装进口为你提供。
概要信息
Extended Product Type:
ASL09-30-01S-81
Product ID:
1SBL103004R8101
Catalog Description:
ASL09-30-01S-81 24VDC Contactor
Long Description:
ASL09 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The ASL..S contactors are the spring terminal version of the ASL... range. The ASL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. ASL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
分类
产品» - 低压产品及系统
» - 控制产品
» - 接触器
» - 模块化接触器
Ordering
Dimensions
Container Information
Package Level 1 Gross Weight:
Package Level 2 Gross Weight:
Environmental
Ambient Air Temperature:
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
Maximum Operating Altitude Permissible:
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: B1 10 g
Closed, Shock Direction: C1 20 g
Closed, Shock Direction: C2 20 g
Open, Shock Direction: B1 5 g
Open, Shock Direction: C1 9 g
Open, Shock Direction: C2 14 g
Shock Direction: A 20 g
Shock Direction: B2 15 g
Resistance to Vibrations acc. to IEC 60068-2-6:
5 ... 300 Hz 3 g Closed position / 2 g Open position
RoHS Status:
Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2009 Q4
Technical
Rated Operational Power AC-3 (Pe):
(220 / 230 / 240V) 2.2 kW
(415V) 4 kW
(440V) 4 kW
(500V) 4 kW
(690V) 4 kW
(400V) 4 kW
Rated Operational Current AC-1 (Ie):
(690V) 40°C 20 A
(690V) 60°C 15 A
(690V) 70°C 12 A
Number of Main Contacts NO:
Number of Main Contacts NC:
Number of Auxiliary Contacts NO:
Number of Auxiliary Contacts NC:
Rated Control Circuit Voltage (Uc):
Certificates and Declarations (Document Number)
Declaration of Conformity - CE:
GOST Certificate:
GOST_POCCCNME77B07822.pdf
2TLA020073R0300 AS-I SPLITTERBOX
1SBL103001M8101 ASL09-30-01-81
1SBL103001M8110 ASL09-30-10-81
1SBL103004M8101 ASL09-30-01S-81
1SBL103004M8110 ASL09-30-10S-81
2TLA020073R0400 AS-I 24DC M12 1M
1SBL103001R8101 ASL09-30-01-81
1SBL103001R8101 ASL09-30-01-81
1SBL103001R8110 ASL09-30-10-81
1SBL103001R8110 ASL09-30-10-81
1SBL103001R8110 ASL09-30-10-81
1SBL103001R8110 ASL09-30-10-81
1SBL103004R8101 ASL09-30-01S-81
1SBL103004R8110 ASL09-30-10S-81
1SBL157001R1310 AF12-30-10-13
1SBL157001R1410 AF12-30-10-14