AF12Z-30-01-20 / 1SBL156001R2001模块化接触器,品牌ABB,上海锐誉实业有限公司为你提供。
概要信息
Extended Product Type:
AF12Z-30-01-20
Product ID:
1SBL156001R2001
Catalog Description:
AF12Z-30-01-20 12-20VDC Contactor
Long Description:
AF12Z contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF..Z contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...250 V 50/60 Hz or 12...250 V DC. AF..Z contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF..Z contactors allow direct control by PLC-output ≥ 24 V DC 500 mA and obtain a reduced holding coil consumption. AF..Z contactors withstand short voltage dips and voltage sags (SEMI F47-0706 compliance) between 24...250 V 50/60 Hz AF..Z contactors have built-in surge protection and do not require additional surge suppressors The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks. (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated for AF..Z-30-..-20 contactors. Only AF..Z-30-..-20 contactors need to respect the polarity on the coil terminals (A1+ and A2-). - Accessories: a wide range of accessories is available.
分类
产品» - 低压产品及系统
» - 控制产品
» - 接触器
» - 模块化接触器
Ordering
Dimensions
Container Information
Package Level 1 Gross Weight:
Environmental
Ambient Air Temperature:
Close to Contactor for Storage -60...+80 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
Maximum Operating Altitude Permissible:
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
Resistance to Vibrations acc. to IEC 60068-2-6:
5...300 Hz 4 g closed position / 2 g open position
RoHS Status:
Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1
Technical
Rated Operational Power AC-3 (Pe):
(220 / 230 / 240V) 3 kW
(380 / 400V) 5.5 kW
(415V) 5.5 kW
(440V) 5.5 kW
(500V) 7.5 kW
(690V) 7.5 kW
Rated Operational Current AC-1 (Ie):
(690V) 40°C 28 A
(690V) 60°C 28 A
(690V) 70°C 24 A
Number of Main Contacts NO:
Number of Main Contacts NC:
Number of Auxiliary Contacts NO:
Number of Auxiliary Contacts NC:
Rated Control Circuit Voltage (Uc):
Technical UL/CSA
Tightening Torque UL/CSA:
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 13 in·lb
Certificates and Declarations (Document Number)
Declaration of Conformity - CE:
GOST Certificate:
GOST_POCCFR.ME77.B07175.pdf
Classifications
1SBL177201R1100 AF16-40-00-11
1SBL177201R1200 AF16-40-00-12
1SBL177201R1300 AF16-40-00-13
1SBL177201R1400 AF16-40-00-14
1SBL156001R2001 AF12Z-30-01-20
1SBL156001R2101 AF12Z-30-01-21
1SBL156001R2201 AF12Z-30-01-22
1SBL156001R2301 AF12Z-30-01-23
1SBL156001R2010 AF12Z-30-10-20
1SBL156001R2110 AF12Z-30-10-21
1SBL156001R2210 AF12Z-30-10-22
1SBL156001R2310 AF12Z-30-10-23
1SBL177501R1100 AF16-22-00-11
1SBL177501R1200 AF16-22-00-12
1SBL177501R1300 AF16-22-00-13
1SBL177501R1400 AF16-22-00-14
1SBL177001R1122 AF16-30-22-11
1SBL177001R1222 AF16-30-22-12