上海锐誉实业有限公司

Contrinex堪泰

  • DW-AD-614-M18-120  Application TypeStandard Rated operating distance sn8 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Pe...

    [2016-03-07]
  • DW-AD-614-M18  Application TypeStandard Rated operating distance sn8 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permis...

    [2016-03-07]
  • DW-AD-614-M12-120  Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Pe...

    [2016-03-07]
  • DW-AD-614-M12  Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permis...

    [2016-03-07]
  • DW-AD-614-M8-121  Application TypeStandard Rated operating distance sn2.5 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 ...

    [2016-03-07]
  • DW-AD-614-M8  Application TypeStandard Rated operating distance sn2.5 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30...

    [2016-03-07]
  • DW-AD-613-M30-120  Application TypeStandard Rated operating distance sn15 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC P...

    [2016-03-07]
  • DW-AD-613-M30  Application TypeStandard Rated operating distance sn15 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permi...

    [2016-03-07]
  • DW-AD-613-M18-120  Application TypeStandard Rated operating distance sn8 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Pe...

    [2016-03-07]
  • DW-AD-613-M18  Application TypeStandard Rated operating distance sn8 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permis...

    [2016-03-07]
  • DW-AD-613-M12-120  Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Pe...

    [2016-03-07]
  • DW-AD-613-M12  Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permis...

    [2016-03-07]
  • DW-AD-613-M8-122  Application TypeStandard Rated operating distance sn2.5 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 ...

    [2016-03-07]
  • DW-AD-613-M8-121  Application TypeStandard Rated operating distance sn2.5 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 ...

    [2016-03-07]
  • DW-AD-613-M8  Application TypeStandard Rated operating distance sn2.5 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30...

    [2016-03-07]
  • DW-AD-613-C80  Application TypeStandard Rated operating distance sn65 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 65...

    [2016-03-07]