上海锐誉实业有限公司

Contrinex堪泰

  • DW-AD-613-C60  Application TypeStandard Rated operating distance sn50 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 65...

    [2016-03-07]
  • DW-AD-613-C40  Application TypeStandard Rated operating distance sn40 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 65...

    [2016-03-07]
  • DW-AD-611-M30-120  Application TypeStandard Rated operating distance sn15 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC P...

    [2016-03-07]
  • DW-AD-611-M30  Application TypeStandard Rated operating distance sn15 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permi...

    [2016-03-07]
  • DW-AD-611-M18-120  Rated operating distance sn8 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permissible rippl...

    [2016-03-07]
  • DW-AD-611-M18  Application TypeStandard Rated operating distance sn8 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permis...

    [2016-03-07]
  • DW-AD-611-M12-120  Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Pe...

    [2016-03-07]
  • DW-AD-611-M12  Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permis...

    [2016-03-07]
  • DW-AD-611-M8-122  Application TypeStandard Rated operating distance sn2.5 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 ...

    [2016-03-07]
  • DW-AD-611-M8-121  Application TypeStandard Rated operating distance sn2.5 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 ...

    [2016-03-07]
  • DW-AD-611-M8  Application TypeStandard Rated operating distance sn2.5 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30...

    [2016-03-07]
  • DW-AD-608-M30  Application TypeStandard Rated operating distance sn10 mm MountingEmbeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB20 … 265 VA...

    [2016-03-07]
  • DW-AD-608-M18  Application TypeStandard Rated operating distance sn5 mm MountingEmbeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB20 … 265 VAC...

    [2016-03-07]
  • DW-AD-608-M12  Application TypeStandard Rated operating distance sn2 mm MountingEmbeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB20 … 265 VAC...

    [2016-03-07]
  • DW-AD-607-M30  Application TypeStandard Rated operating distance sn10 mm MountingEmbeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB20 … 265 VA...

    [2016-03-07]
  • DW-AD-607-M18  Application TypeStandard Rated operating distance sn5 mm MountingEmbeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB20 … 265 VAC...

    [2016-03-07]