上海锐誉实业有限公司

SICK西克

KT5G-2N3151
上海锐誉订购

KT5G-2N3151

型 号:KT5G-2N3151
品 牌:SICK西克
价格-货期:请咨询我司商务
电 话:021-50189957
邮箱:rymro@sina.com
KT5G-2N3151产品详细信息:

SICK西克KT5G-2N3151传感器年中特惠,上海锐誉承诺,为你提供各种德国传感器。

Contrast sensors
KT5, KT5-2 Potentiometer

Type KT5G-2N3151
Part No. 1018039


At a glance
Tough, metal housing
Manual switching threshold adjustment with optical adjustment indicator
Green or white LED technology
Models with analog output
Switching frequency of 10 kHz
Various sensing distances and light spot directions
M12 plug can be rotated 90°

Your benefits
All standard print marks and contrasts are detected
Reliable operation, even with jittering webs and high-gloss materials
High positioning accuracy improves packaging quality
Various sensing distances, light spot directions and light emissions make individual configuration and simple integration into the production process possible






Features
Sensing distance 1): 10 mm
Sensing distance tolerance: ± 3 mm
Light source 2): LED
Wave length: 520 nm
Light emission: Long and short side of housing, exchangeable
Light spot size: 1.2 mm x 4.2 mm
Light spot direction 3): Round
Output function: Light/dark switching
Type of light: Visible green light
Dimensions (W x H x D): 30.4 mm x 53 mm x 80 mm
Housing design (light emission): Rectangular
Teach-in mode: Manual adjustment, potentiometer
1) From front edge of lens 2) Average service life: 100,000 h at TU = +25 °C 3) In relation to long side of housing


Mechanics/electronics
Ripple 1): ≤ 5 Vpp
Power consumption 2): < 80 mA
Switching frequency 3): 10 kHz
Response time 4): 50 µs
Switching output: NPN: HIGH = approx. VS / LOW ≤ 2 V
Switching mode: NPN
Analog output QA: 0.3 mA ... 10 mA
Connection type: Connector M12, 4-pin
Protection class 5): II
Circuit protection: Output Q short-circuit protected, Interference pulse suppression, UV connections, reverse polarity protected
Enclosure rating: IP 67
Weight: 400 g
Housing material: Metal, Zinc diecast
Output current Imax.: 100 mA
Supply voltage: 10 V DC ... 30 V DC 6)
1) May not exceed or fall below Uv tolerances 2) Without load 3) With light/dark ratio 1:1 4) Signal transit time with resistive load 5) Reference voltage DC 50 V 6) Limit values: operation in short-circuit protected network max. 8 A


Ambient data
Shock load: According to IEC 60068
UL File No.: NRKH.E181493 & NRKH7.E181493
Ambient operating temperature: -10 °C ... +55 °C
Ambient storage temperature: -25 °C ... +75 °C