上海锐誉实业有限公司

SICK西克

WF80-60B410叉式传感器
上海锐誉订购

WF80-60B410叉式传感器

型 号:WF80-60B410
品 牌:SICK西克
价格-货期:请咨询我司商务
电 话:021-50189957
邮箱:rymro@sina.com
WF80-60B410产品详细信息:

WF80-60B410叉式传感器原装,SICK分销商-上海锐誉为你提供,期待你的咨询。

Fork sensors
WF, WFnext

Type WF80-60B410
Part No. 6028441


At a glance
Infrared light source
Simple and accurate adjustment via teach-in or manually via "+"/"-" buttons
Fast response time (max. 100 µs)
PNP and NPN switching output
Light/dark switching function
21 different models with different fork widths and depths
Rugged, IP 65 aluminum housing

Your benefits
Fast response time and fine resolution ensure reliable detection even at high speeds
Infrared light source provides excellent ambient light immunity
User friendly setting via teach-in or "+”/"-” button
A wide range of different fork sizes enables flexible installation
The aluminum housing meets all requirements for use in harsh industrial conditions






Features
Functional principle: Optical detection principle
Fork width: 80 mm
Fork depth: 59 mm
Label detection: -
Light source: LED
Type of light: Infrared light
Adjustment: Manual ("+"/"-" button)
Output function: Light/darkswitching, selectable via button
Housing design (light emission): Fork shaped
Minimum detectable object (MDO): 0.2 mm



Mechanics/electronics
Ripple 1): < 10 %
Power consumption 2): 40 mA
Switching frequency 3): 10 kHz
Response time 4): 100 µs
Stability of response time: ± 20 µs
Switching output: NPN: HIGH = approx. VS / LOW ≤ 2 V
PNP: HIGH = VS- ≤ 2 V / LOW approx. 0 V
Switching mode: PNP/NPN
Output current Imax.: 100 mA
Initialization time: 100 ms
Connection type: Connector M8, 4-pin
Protection class 5): III
Circuit protection: UV connections, reverse polarity protected
Output Q short-circuit protected
Interference pulse suppression
Enclosure rating: IP 65
Weight: Ca. 36 g ... 160 g 6)
Housing material: Aluminum, Metal
Supply voltage: 10 V DC ... 30 V DC 7)
Ambient light immunity: Sunlight: ≤ 10,000 klx
Fieldbus interface: -
1) May not exceed or fall short of VS tolerances 2) Without load 3) With light/dark ratio 1:1 4) Signal transit time with resistive load 5) Reference voltage DC 50 V 6) Depending on fork width 7) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A


Ambient data
Shock load: According to EN 60068-2-27
UL File No.: NRKH.E191603
Ambient operating temperature: -20 °C ... +60 °C 1)
Ambient storage temperature: -30 °C ... +80 °C
1) Do not bend below 0 °C