BZ 16-03F IP69 Extreme
用于极端环境的安全传感器
物料号: 1355632
特征/选项
高防护等级IP69版本:适用于在100 bar的80℃开水,从距离100 mm的不同方向喷射清洗
热塑性塑料外壳
寿命长
输入的区别:感应/磁操作原理
内部监控,高级操作保护
无源输出
信号触点
LED状态灯
3个常闭触点
操作面板:从正面“F”操作
额定感应距离Sn = 12 mm
接线箱
注释: 下单时请注意国家对国际认证的要求!
注释
操作件不包含在订购的开关中
订购包含1个M20x1.5-IP69的格兰头和2个M20x1.5的固定螺钉
技术参数
标准 EN 61000-6-1, -2, -3, -4;
EN 60947-5-2; EN 60947-5-3;
EN ISO 14119; EN 60204-1;
EN ISO 13849-1; DIN EN 62061;
2004/108/EG
外壳 glass-fibre reinforced, shock-proof thermoplastic (PA 66), self-extinguishing UL 94-V0
传感器类型 type 4 interlocking device
编码等级 low coding
拧紧力矩 Mounting screws of sensor: max. 2 Nm
cover of sensor: max. 1.5 Nm
actuator: max. 2 Nm
感应距离 sn = 12 mm (10 mm with flush mounting)
sao = 10 mm (8 mm with flush mounting)
sar = 25 mm
(Minimum distance 2 mm for approach from side.)
磁滞现象 approx. 6 mm
横向公差 ≤ 3 mm
重复性 < 1 mm
安全相关数据:*
EN ISO 13849-1: 2008-12 PL e (is only achieved in combination with a safety module)
DCavg 96 %
类别 3
B10d 20 百万
TM max. 20 years
系统平均无危险故障时间 100 years
DIN EN 62061 SIL CL 3
PFHd ≥ 4.29 x 10-8 1/h
安全要求 nop
hop 8 h/day
dop 220 days/year
tzyklus 20 s/Zyklus
Ie/Ue 140 mA/24 VDC ± 15 %
(reverse voltage protected)
无负载电源电流 I0 ≤ 70 mA
短路保护 0.25 A (slow blow)
输出 2 enabling paths (2 NC)
1 signalling contact (1 NC)
开关电压 max. 30 VAC/DC
限制短路电流 100 A
短路保护 4 A (gG/gN) incoming series-connected
信号触点的输出触点的应用类别
AC-15; DC-13
AC-12; DC-12
输出触点的额定工作电流/电压 max. 3 A/24 VAC/DC, min. 10 mA/5 VAC/DC
信号触点的额定工作电流/电压 max. 1 A/24 VAC/DC, min. 100 μA/100 mVDC
Ui 250 VAC
Uimp 1 kV
电压降 < 0.6 V
过电压类别 III
开关频率 max. 1 Hz
迟滞时限 tv < 300 ms
风险时刻 max. 165 ms
防污等级 3
防护等级 IP 69 (IEC/EN 60529)
环境温度 0 °C … +55 °C
贮藏和运输温度 –20 °C … +70 °C
机械寿命 50 mio. operations
输出电阻 AgSnO self-cleaning, positive-guided
信号触点 AgNi, gold-plated
输出触点电阻 100 mΩ in new condition
信号触点电阻 max. 30 mΩ
连接类型 cable entry M20 x 1.5, wiring compartment with socket screw clamps 8-pole
线缆横截面 min. 0.14 mm2 / AWG 28
max. 1.5 mm2 / AWG 16
产品认证
* The safety-related data are based on a load of 24 V / 0.1 A / DC-1 for the enabling paths.
With higher load currents for the enabling paths and other requirement rates nop, the safety-related data vary from the given data and can be provided on request.
Contact diagram
Actuating planes
Axial misalignment
Approach from side
BZ 16-12F IP69 Extreme 1355627
BZ 16-12T IP69 Extreme 1355630
BZ 16-03F IP69 Extreme 1355632
BZ 16-03T IP69 Extreme 1355634
BZ 16-B1 90570007 1165032
Typenbezeichnung alte Mat.-Nr. Mat.-Nr.
HS Si 4 1Ö/1S-2m -40°C IP69 Extreme 20469201 1189889
HS Si 4 1Ö/1S-5m -40°C IP69 Extreme 20469501 1189898
HS Si 4 2Ö-2m -40°C IP69 Extreme 20479201 1189899
HS Si 4 2Ö-5m -40°C IP69 Extreme 20479501 1189900
MC 4 05.00.8221 1181771
Typenbezeichnung alte Mat.-Nr. Mat.-Nr.
RC Si M30 1Ö/1S-2m-Niro-IP69 Extreme 23009202 1188973
RC Si M30 1Ö/1S-5m-Niro-IP69 Extreme 23009502 1188976
RC Si M30 1Ö/1S-10m-Niro-IP69 Extreme Neu 1482181
RC Si M30 1Ö/1S-LED-2m-Niro IP69 Extreme 23009201 1186991
RC Si M30 1Ö/1S-LED-5m-Niro IP69 Extreme auf Anfrage
RC Si M30 2Ö-2m-Niro-IP69 Extreme 23059201 1188981
RC Si M30 2Ö-5m-Niro-IP69 Extreme 23059501 1182750
RC Si M30 2Ö-10m-Niro-IP69 Extreme Neu 1482210
RC Si M30 2Ö-LED-2m-Niro IP69 Extreme 23050202 1188157
RC Si M30 2Ö-LED-5m-Niro IP69 Extreme auf Anfrage
MC 30 Niro Extreme 05.00.8220 1182385
Typenbezeichnung alte Mat.-Nr. Mat.-Nr.
RC Si 56 1Ö/1S-2m-IP69 Extreme 25609201 1188983
RC Si 56 1Ö/1S-5m-IP69 Extreme 25609501 1188989
RC Si 56 1Ö/1S-10m-IP69 Extreme Neu 1482241
RC Si 56 1Ö/1S LED-2m IP69 Extreme auf Anfrage
RC Si 56 1Ö/1S LED-5m IP69 Extreme auf Anfrage
RC Si 56 2Ö-2m IP69 Extreme 25659201 1188993